DES-4122 Exam Dumps Update – Easy to pass EMC DES-4122 exam

You must have reliable learning material to prepare for the EMC DES-4122 exam. passitdump.com is ready for you, the new DES-4122 exam dump, welcome. The updated DES-4122 exam dumps help you practice valid DES-4122 exam questions and answers before taking the MC DES-4122 exam. This way you can pass the exam easily.

These questions are from DES-4122 free dumps.

Question 1:

A technician is creating a virtual disk in the iDRAC (2x 4 TB NL-SAS in RAID 1) to install Windows 2016 They manually boot to the OS installation media without using the Lifecycle Controller OS Deployment wizard Only the first 2048 GB on the virtual disk can be partitioned

How should the technician obtain access to the remaining 2 TB (approximately) of storage?

A. Use the Lifecycle Controller OS Deployment Wizard to deploy the OS on this server

B. Delete the 4 TB virtual disk and create a virtual (boot) disk no larger than 2048 GB

C. Upgrade to a newer version of the operating system

D. Use F2 to go into the BIOS, change the BIOS boot mode to UEFI, and try again

Correct Answer: C


Question 2:

Where is the data stored to allow Easy Restore to complete a system board replacement successfully?

A. NAND Flash module on the disk drive mid plane

B. IDSDM SD card

C. vFlash SD card

D. Serial Flash storage in the server\’s front panel

Correct Answer: C


Question 3:

A technician needs to repurpose a Dell EMC PowerEdge server. The server has dual processors with 18 cores each The OS only “sees” 24 threads in total.

Which setting should the technician change in Processor Settings in the System BIOS?

A. System Profile

B. Virtualization Technology

C. HyperThreading

D. Number of Cores per Processor

Correct Answer: A


Question 4:

What are the default settings used when applying firmware and a configuration to a replaced part using the Lifecycle Controller?

A. Firmware: Upgrade to latest available version Configuration Apply always

B. Firmware Allow version upgrade only Configuration: Disabled

C. Firmware: Match firmware of replaced part Configuration Apply always

D. Firmware Disabled Configuration Apply only if firmware match

Correct Answer: C


Question 5:

What is the purpose of the Silicon-Based Hardware Root of Trust feature in Dell EMC PowerEdge 14G servers?

A. Ensures that the installed operating system is authentic

B. Ensures that the server has a valid Service Tag number

C. Ensures that no unauthorized BIOS or firmware codes are run

D. Ensures that the server boots only when connected to a verified network

Correct Answer: C


Question 6:

An engineer is checking a newly delivered Dell EMC PowerEdge R640 server that will be deployed for a new database environment

The inventory consists of:

The server power configuration will be set for gnd redundancy The management switch is 1000 Base-T and the top of rack switches 10Gb

What additional component(s) is needed for this configuration?

A. Hot-plug power supply, 750 W – qty 1

B. Hot-plug power supply, 1100W – qty 1

C. Dell Networking, cable, 40GbE (QSFP ) to 4 x 10GbE SFP passive copper breakout cable, 3 meters – qty 2

D. C20 to C21, PDU style, 250 V, 16 Amp, 3 5 meters power cord – qty 2

Correct Answer: D


Question 7:

What is a systems management console solution optimized for monitoring and managing Dell enterprise and remote office hardware?

A. SupportAssist Enterprise

B. iSM

C. OpenManage Essentials

D. iDRAC9

Correct Answer: C


Question 8:

After completing a disk rebuild operation, a technician needs to configure the system so that the rebuild process happens faster the expense of slowing users down.

Which setting should be changed?

A. Rebuild Rate in the BIOS settings

B. System Profile to Performance in the BIOS settings

C. System Profile to Performance in the iDRAC GUI

D. Rebuild Rate in the iDRAC GUI

Correct Answer: D


Question 9:

An engineer wants to fully leverage Microsoft Windows Server 2016 for TPM-based guarded host deployment of a 14G server Which BIOS settings need to be used for installing the Windows server?

A. Option A

B. Option B

C. Option C

D. Option D

Correct Answer: C


Question 10:

A company that has very specific firmware requirements has acquired Dell EMC PowerEdge servers Any replaced parts of the type must match the original parts identically. The procedure must be as simple as possible with minimal risk.

What action should a technician take to help accomplish this goal?

A. Configure servers to access the remote firmware repository

B. Enable the Match Firmware of Replaced Part setting in the system BIOS

C. Install and configure a repository manager

D. Enable the Collect System Inventory On Restart (CSIOR) attribute

Correct Answer: A


Question 11:

A technician installs eight servers into a fully operational rack with top of rack switch Each server has a quad 1Gb NIC and redundant power supplies The company uses iDRAC in shared LOM mode with LOM1 as the selected NIC

What should the technician do to verify iDRAC connectivity on each server?

A. iDRAC Datacenter license is installed.

B. Ethernet port LOM1 is cabled and the link light is green.

C. iDRAC dedicated NIC port is cabled and the link light is green

D. iDRAC Enterprise license is installed

Correct Answer: C


Question 12:

Dell EMC PowerEdge 14G servers support which technology?

A. Quicksync 1.0

B. Intel Boot Guard

C. AMD GuardMI

D. iDRAC8

Correct Answer: C


Question 13:

Which type of access is known as Firmware RACADM on a Dell EMC PowerEdge server?

A. Accessing RACADM running the Dell Toolkit

B. Accessing RACADM with OpenManage software

C. Logging into iDRAC using SSH or Telnet

D. Logging into iDRAC through Boot Manager

Correct Answer: C


Question 14:

A Dell EMC PowerEdge 14G server uses Intel OPTANE DC Persistent Memory in App Direct mode. What is the minimum size DIMM supported for this type of memory?

A. 64 GB

B. 128 GB

C. 256 GB

D. 512 GB

Correct Answer: C


Question 15:

A technician needs to change the iDRAC password on a Dell EMC PowerEdge 14G server in a lights-out datacenter. The be rebooted because it is in production. The iDRAC is configured with the default credentials How could the technician change the iDRAC password?

A. SupportAssist Enterprise

B. iDRAC Web GUI

C. OpenManage Server Administrator

D. Virtual Console; press F2 after rebooting system

Correct Answer: A