Up-to-date 5V0-21.21 Exam Dumps [2023] Prepares You

The latest 5V0-21.21 exam dumps are here for everyone to prepare for the exam. Passitdump provides you with the new 5V0-21.21 exam dumps 2023 to help you easily pass the VMware5V0-21.21 exam.

5V0-21.21 exam dumps 2023 provides you with valid exam questions and answers to ensure that you can understand the exam content correctly and ultimately win the exam.

Free sample questions of 5V0-21.21 free dumps are provided here. All the following questions are from the latest real 5V0-21.21 dumps.

Question 1:

An administrator is setting up vSAN file services on a vSAN cluster.

Which two security policies on the distributed port groups are automatically enabled in the process? (Choose two.)

A. Forged Transmits

B. Promiscuous Mode

C. DVFiltering

D. Jumbo Frames

E. MacLearning

Correct Answer: AB

Reference: https://www.yellow-bricks.com/2020/04/15/vsan-file-services-considerations/


Question 2:

A customer is planning to deploy a vSAN cluster to host their in-house distributed ERP system. The hardware specifications for their server nodes include:

2 x Intel Xeon CPU E5-2697 v3 @ 2.60GHz 1TB memory

Which boot device is supported for the vSAN ESXi nodes for this customer?

A. A 16GB single-level cell (SLC) SATADOM device must be used.

B. A 4GB USB or SD device must be used.

C. A 16GB multiple-level cell (MLC) SATADOM device must be used.

D. ESXi Hosts must boot from a PMEM device.

Correct Answer: C


Question 3:

A company hosts a vSAN 7 stretched cluster for all development workloads. The original sizing of a maximum of 250 concurrent workloads in the vSAN cluster is no longer sufficient and needs to increase to at least 500 concurrent workloads within the next six months.

To meet this demand, the original 8-node (4-4-1) cluster has recently been expanded to 16 nodes (8-8-1).

Which three additional steps should the administrator take to support the current growth plans while minimizing the amount of resources required at the witness site? (Choose three.)

A. Add the new vSAN witness appliance to vCenter Server.

B. Deploy a new large vSAN witness appliance at the witness site.

C. Configure the vSAN stretched cluster to use the new vSAN witness.

D. Deploy a new extra large vSAN witness appliance at the witness site.

E. Upgrade the vSAN stretched cluster to vSAN 7.0 U1.

F. Configure the new vSAN witness as a shared witness appliance.

Correct Answer: BCF


Question 4:

Upon investigating a workload performance issue, a vSAN administrator observed a high backend IOPs on a vSAN cluster.

Which two causes explain this behavior? (Choose two.)

A. The cluster DRS threshold has been set to Aggressive.

B. There is a vSAN node failure.

C. The vSAN Resync throttling is enabled.

D. The object repair timer value has been increased.

E. The vSAN policy protection level has changed from FTT=0 to FTT=1.

Correct Answer: CE

Reference: https://core.vmware.com/resource/troubleshooting-vsan-performance#_Toc536646878


Question 5:

An administrator wants to deploy a desktop and application virtualization solution on top of vSAN. Which VMware product should the administrator install?

A. VMware Dynamic Environment Manager

B. VMware Horizon Apps

C. VMware Workspace One Access

D. VMware Horizon

Correct Answer: D


Question 6:

An administrator has been tasked with enabling encryption for existing virtual machines on a vSAN cluster. Which three prerequisites must be satisfied before completing the task? (Choose three.)

A. Create an encryption storage policy

B. Enable Data-In-Transit encryption first

C. Enable that the virtual machines are powered on

D. Verify if a role with privilege “Cryptographic operations.Encrypt new” is assigned

E. Verify if a role with privilege “Cryptographic operations.Migrate” is assigned

F. Establish a trusted connection with the KMS

Correct Answer: CDF


Question 7:

An architect is designing for a production vSAN cluster, and the customer introduced these requirements

related to File Services:

A minimum of 12 files shares.

30TB NFS capacity to mount workload VMs.

What should be the architect\’s recommendations?

A. Point out the risks regarding putting the hosts in maintenance mode in terms of FSVM.

B. Confirm on all of the requirements and move forward with the physical design.

C. Raise concerns regarding support when running VMs on an NFS share as risk.

D. Highlight the required number of nodes required for the vSAN cluster as a constraint.

Correct Answer: D


Question 8:

An administrator has received an alert indicating that a single capacity device is close to failing within the production vSAN Cluster. The administrator must now complete preemptive maintenance on the vSAN Cluster without impacting the availability of workloads or vSAN File Services.

The following information is known about the vSAN Cluster: vSAN 7.x Cluster vSAN node count: 8 De-Duplication and Compression: Enabled. Encryption: Disabled Current Utilization: 45% Disk Groups: 2 Devices per node: 2 x 400 GB SSD, 6 x 1.8 TB SSD

Which three steps should the administrator take to successfully complete the task? (Choose three.)

A. Remove the affected Disk Group from the vSAN Cluster, and choose Full Data Migration.

B. Replace the failed disk with a storage device that is identical in class and capacity.

C. Remove the affected Disk Group from the vSAN Cluster, and choose No Data Migration.

D. Replace the failed disk with a storage device that is identical in class but smaller in capacity.

E. Put the affected vSAN host into maintenance mode to physically replace the storage device.

F. Remove the affected Disk from the Disk Group, and choose Full Data Migration.

Correct Answer: ABF


Question 9:

A 30-minute power maintenance window has been approved on Sunday. Due to a delay, the maintenance took 20 minutes longer to finish.

During this time, the vSAN administrator noticed that one of the clusters nodes was affected by a power shortage, as it was connected to an affected power source. The default vSAN storage policy has been applied.

What will be the status of the vSAN objects on the affected host immediately after it is recovered?

A. The cluster will be partitioned and the vSAN host will need to be rejoined.

B. A rebuild of the affected objects will occur.

C. All objects will remain accessible.

D. All objects on the affected host will be lost.

Correct Answer: B


Question 10:

After a vSAN Witness Appliance network configuration, the vSAN administrator notices that vSAN traffic flows from vmk0 (Management Traffic) rather than vmk1 (vSAN Traffic).

Which step should be taken to resolve this issue?

A. Configure vmk0 with IP address on the same range as that of vmk1.

B. Tag the vmk0 for vSAN traffic.

C. Configure vmk1 with IP address on the different network than that of vmk0.

D. Tag the vmk1 for Witness traffic.

Correct Answer: A

If both vmk0 and vmk1 are configured on the same range, a multihoming condition will occur and vSAN traffic will flow from vmk0, rather than vmk1.

Reference: http://www.vmwarearena.com/vsan-stretched-cluster-how-to-configure-vsan-witnessappliance/


Question 11:

A customer has upgraded to vSAN 7, but there is still an existing legacy host which must be removed from the vSAN cluster.

Which three steps must an administrator take to successfully remove this host from the vSAN cluster? (Choose three.)

A. Place the host in maintenance mode with Ensure Accessibility

B. Disconnect from vCenter Server

C. Place the host in maintenance mode with Full Data migration

D. Place the host in maintenance mode with no data migration

E. Remove from vSAN cluster

F. Delete the disk group(s) on the legacy host

Correct Answer: CEF

Reference: http://www.vexpertconsultancy.com/2019/06/step-by-step-remove-a-node-permanently-from-avsan-cluster/


Question 12:

An administrator is tasked with setting up Kerberos authentication only for the vSAN File services.

Which version of Kerberos must be selected if the NFS version is v4.1?

A. krb5i

B. krb4

C. krb5

D. krb5p

Correct Answer: A

Reference: https://core.vmware.com/resource/best-practices-running-nfs-vmware-vsphere


Question 13:

An administrator wants to enable encryption on an existing vSAN cluster that already contains virtual machines.

Which additional step should the administrator take to ensure no data is lost during the encryption process?

A. Select ‘Erase disks before use’ check box when enabling encryption on a vSAN cluster.

B. Make vCenter Server trust the KMS, either by trusting the KMS or by uploading a KMS certificate.

C. Ensure that the vSAN Encryption is enabled by default on the existing cluster to encrypt old and new data.

D. Disable vSphere Distributed Resources Schedule (DRS) on the vSAN cluster.

Correct Answer: A

Reference: https://core.vmware.com/resource/vsan-data-rest-encryption#sec7014-sub2


Question 14:

An organization has two vSAN clusters managed by the same vCenter Server, each providing 100TB of storage. The first cluster runs at 75% of its storage capacity, and the second cluster runs at 50% of its storage capacity.

The company also has the following:

An iSCSI array of 300TB. which runs at 76% of its capacity A NAS system of 200TB, which runs at 10% of its capacity A Fiber channel (FC) array of 300TB, which runs at 80% of its capacity

The administrator is asked to add an additional 25TB of storage to the first cluster. The administrator is also made aware that there is no budget to purchase new hardware and that the vSAN Storage Policy Based Management must be kept in place.

Which storage option will work for this use case?

A. Create an HCI Mesh using the first cluster\’s datastore.

B. Obtain additional free capacity from the existing NAS storage.

C. Obtain additional free capacity from the existing FC storage.

D. Create an HCI Mesh using the second cluster\’s datastore.

Correct Answer: B


Question 15:

Which statement accurately describes the result when proper VM Storage Policy Affinity Rules on a stretched vSAN cluster are set?

A. When a site is disconnected, the VM will lose access to its VMDK.

B. When a site is disconnected, the VM will continue to have access to its VMDK.

C. Bandwidth is unnecessarily sent across the inter-site link.

D. Proper policies result in higher inter-site bandwidth utilization.

Correct Answer: A