Using NS0-520 Dumps Updated Learning Materials Pass NS0-520 Exam

NS0-520 dumps updates are online to help you pass the NetApp NS0-520 exam. The real updated NS0-520 dumps come with practice questions and answers from passitdump.com, peruse the free NS0-520 dumps questions below as it is the right way to prepare for the NetApp Certified Implementation Engineer – SAN ONTAP exam.

We have sample questions for NS0-520 free dumps. You can download and check the real questions of updated NS0-520 dumps.

Question 1:

A customer wants to deploy NVMe/FC along with an existing FC SAN fabric using ONTAP 9.8. In this scenario, which two actions are correct? (Choose two.)

A. Enable NVMe/FC on the existing FC SVM.

B. Create new zoning on fabric switches.

C. Upgrade your FC switches from 16 GB to 32 GB.

D. Use existing zoning on fabric switches.

Correct Answer: CD


Question 2:

Click the Exhibit button.

You are configuring a new NetApp ONTAP cluster and are connecting the nodes to Cisco MDS SAN switches. You connect one of the nodes to switch port fc1/11 and run the commands that are shown in the exhibit. The SAN LIFs are enabled but are not operationally online, and none of the SAN hosts can access their LUNs on the ONTAP cluster.

In this scenario, which configuration would cause this problem?

A. NPIV is not enabled on the switches.

B. Interoperability mode is not enabled on the switches.

C. NPV is not enabled on the switches.

D. The in-order guarantee is not enabled on the switch.

Correct Answer: B


Question 3:

You are installing an AFF A250 system with ONTAP 9.8 software. Your customer asks you about the recommended LIF configuration for the iSCSI protocol.

In this scenario, which two statements are correct? (Choose two.)

A. Each node in an iSCSI configuration must be connected to a minimum of two Ethernet switches.

B. Each SVM in an iSCSI configuration must have a minimum of two LIFs per node.

C. All LIFs from the SVM are connected to a single Ethernet switch.

D. Each SVM in an iSCSI configuration must have a minimum of one LIF per node.

Correct Answer: AC


Question 4:

A customer has a 4-node cluster consisting of a FAS8020 system and an AFF A220 system that is running iSCSI workloads across two separate SVMs. The FAS8020 system is reaching end of support, so they add a new AFF A400 system to migrate workloads off the FAS8020 system. The customer wants to migrate data off the FAS8020 aggregate n1_aggr1 on SVM2 to the AFF A400 aggregate n5_aggr1 on SVM1.

In this scenario, which NetApp command would accomplish this task?

A. volume move

B. aggregate reallocation

C. volume reallocation

D. volume rehost

Correct Answer: D


Question 5:

Which NetApp tool provides a detailed inventory of SAN components?

A. Hardware Universe

B. Active IQ Config Advisor

C. Interoperability Matrix Tool

D. Active IQ OneCollect

Correct Answer: C


Question 6:

You want to move a SAN LIF and preserve its configuration information and avoid rezoning the switch fabric.

In this scenario, which two steps must be performed to fulfill this goal? (Choose two.)

A. Keep the SAN LIF online before it is moved.

B. Take the SAN LIF offline before it is moved.

C. Move the SAN LIFs to another node in a cluster on different storage virtual machines (SVMs).

D. Move the SAN LIFs to another node in a cluster on existing storage virtual machines (SVMs).

Correct Answer: BD


Question 7:

Your customer asks you how to connect a host for SAN access to the newly installed AFF A400 system. In this scenario, which two statements are correct? (Choose two.)

A. Direct connection to the nodes from the hosts with FC is not supported.

B. Direct connection to the nodes from the hosts with iSCSI is not supported.

C. Direct connection to the nodes from the hosts with iSCSI is supported.

D. Direct connection to the nodes from the hosts with FC is supported.

Correct Answer: BD


Question 8:

Click the Exhibit button.

In an NVMe/FC environment, the host cannot discover the namespace on the AFF system. Referring to the exhibit, what is the problem?

A. The NQN is not correct.

B. The host MPIO drivers are not installed.

C. NVMe is not supported on the FC adapter.

D. The NVMe service is not running on the SVM.

Correct Answer: B


Question 9:

You are designing a new 4-node AFF A400 SAN cluster with 20 iSCSI hosts. Each AFF A400 node will have four data LIFs. Each iSCSI host needs to access every LUN over two LIFs per node on every SAN node.

In this scenario, which NetApp SAN feature enables this connectivity?

A. selective LUN mapping

B. port sets

C. HBA queue depth

D. asymmetric namespace

Correct Answer: A


Question 10:

You are planning on implementing a new SAN on AFF A400 controllers. The data set consists of unique 1 KB files that will be encrypted before being written to the SAN.

In this scenario, which ONTAP inline storage efficiency will provide 4:1 savings for this workload?

A. autogrow

B. deduplication

C. compression

D. compaction

Correct Answer: B


Question 11:

While changing the network connections on your ONTAP cluster from twinax to fiber, the ports experience network connectivity issues. You want to verify which speeds the ports support and ensure that you have supported transceivers.

In this scenario, which two action would accomplish this task? (Choose two.)

A. Use Hardware Universe to determine the supported port speeds.

B. Use the Interoperability Matrix Tool to determine the supported port speeds.

C. Use Hardware Universe to determine the supported transceivers.

D. Use the Interoperability Matrix Toll to determine the supported transceivers.

Correct Answer: BC


Question 12:

An administrator is configuring their existing Ethernet network switches to provide iSCSI LUNs to several servers. The network switches are also used for other traffic from various hosts.

In this scenario, which statement is true?

A. Use multiple VLANs to isolate iSCSI traffic from other network traffic.

B. Configure the MTU size to be larger on the switch and storage than on the host.

C. Increase the ratio of access ports to trunk ports to 2:1.

D. NetApp recommends using the same LIFs for NFS and iSCSI traffic.

Correct Answer: D


Question 13:

You are configuring FC ports on front-end SAN switches for a 4-node MetroCluster configuration across two data centers. You need to ensure that each data center serves FC LUNs when a FC port goes offline in one data center.

In this scenario, which front-end switch setting must be modified to avoid overlap when a new port comes online?

A. NPIV enabled

B. ANA mapped

C. WWPN reject

D. WWNN reject

Correct Answer: C


Question 14:

You are testing FPC path failures on a 2-node NetApp AFF All SAN Array and verify that persistent ports are correctly enabled. Before testing, a host sees four optimized paths to a LUN. You perform a node takeover and re-check the host.

Which statement is true after the node takeover?

A. The host sees two optimized paths and two non-optimized paths to the LUN.

B. The host sees two optimized paths and two dead paths to the LUN.

C. The host sees two non-optimized paths and two dead paths to the LUN.

D. The host sees four optimized paths to the LUN.

Correct Answer: A


Question 15:

You have implemented FabricPool on your AFF ASA ONTAP 9.8 cluster. An archived database has become very active, and it requires FabricPool adjustments.

Which two steps are required to address this issue? (Choose two.)

A. Set the space guarantee on the volume.

B. Set the tiering-policy to none.

C. Use the promote cloud-retrieval-policy.

D. Remove all Snapshot copies.

Correct Answer: AB